iotracker Synchronization Unit
Technical specifications
- Number of cameras: Up to 8 iotracker cameras per synchronization unit. Can be extended by daisy-chaining multiple synchronization units.
- Modes: Two time-shifted synchronization groups (prevents IR strobe interference). Master/slave mode. Can be driven from external circuitry (TTL-compatible voltage-level or 20mA current-loop signal). All features configurable via DIP switches.
- Connectors: 8x RG-59 BNC trigger-signal output (front), 1x 3-pin Mini-DIN VESA stereo signal input (front), 1x RG-59 BNC trigger-signal input (back).
- Output signal: 20mA current-loop.
- Input signal: Voltage-level (3.3V and 5V TTL-compatible) or 20mA current-loop.
- Shutter-glasses: Interoperable with IR-controlled Crystal Eyes 3 shutter-glasses (with E2 emitter) from REAL D Scientific. (under development - available soon!)
- Power: 5V DC, 1A, 5.5mm/2.5mm power jack.
- Dimensions: 105.0mm/41.34"(W) x 52.0mm/20.47"(H) x 50.0mm/19.69"(D, without BNC jack